Sign In | Join Free | My himfr.com
Home > Haze Measurement Instrument >

DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine

    Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
     
    Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
    • Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
    • Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
    • Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
    • Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
    • Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers
    • Buy cheap DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine from wholesalers

    DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine

    Ask Lasest Price
    Brand Name : CHN spec
    Model Number : DS-37D
    Certification : CE
    Price : negotiable
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 1000 per month
    Delivery Time : 5-7 days
    • Product Details
    • Company Profile

    DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine

    Benchtop spectrophotometer


    The DS-37D series is equipped with its own spectroscope engineer, which can increase light output by 50% and spectral resolution by 30%. It shows more pivot points This change is approximately 350% and requires an input calibration algorithm.



    Benchtop spectrophotometer DS-37D

    DS-37D:repeatability0.005,Inter-instrument agreement0.12


    · Equipped with two types of lighting sources: pulse xenon lamp and LED

    · 37 standard light sources, 40+measurement indicators

    ·Automatic recognition of four apertures switching

    ·Temperature and humidity calculation compensation function

    ·7-inch touch screen, Android operating system

    · Provide powerful ColorExpert computer data management software

    · Can save data to the cloud and follow the account to prevent loss

    · Support PC end export or printing of data test reports

    · Support color matching software to provide more formula inspiration and improve color matching efficiency


    Differential spectrum engine improves overall measurement performance


    The optical input of the sensor increases by 50%, the spectral resolution increases by 30%, the signal-to-noise ratio is higher, the repeatability, inter instrument differences, and the data is highly consistent with the standard instrument data. The inter instrument consistency can reach 0.08, and the repeatability can reach 0.005. The relevant technology is protected by Chinese invention patents.


    Double optical path design improves repeatability accuracy repeatability accuracy dE*ab≤0.005


    Dual light source mode designer, light source driver, high-performance equipment, and media driver tool design. The difference between high standard media speed, accuracy, stability, and inter is protective. Innocent people in China and innocent people in the United States protect related technologies.

    Innovative 1nm resolution grating spectroscopy technology


    Innovation is the soul of CHNSpec. After nearly 10 years of dedicated research, the grating combined array sensor made by the innovative MEMS process makes the color measurement more accurate on the basis of 1nm spectral resolution, once again leading the industry innovation direction and greatly improving the technical performance of the product. The relevant technologies are protected by Chinese invention patents.


    Excellent inter-instrument agreement:dE*ab≤ 0.08,


    High repeatability accuracy:dE*ab≤0.005, ensure accurate data transfer between factories

    High precision automatic calibration


    Advanced automatic calibration technology greatly improves long-term repeatability of instruments. Under constant temperature, the dE*ab of day 1 and day 30 can still reach 0.01. At any temperature change from 0℃ to 40℃, dE*ab can reach less than 0.1.

    Technical Parameter


    Benchtop spectrophotometer


    Model


    DS-36D


    DS-37D


    DS-39D

    Lighting/measuring conditions



    Reflection:d/8(diffuse illumination,8°direction reception)


    SCI(Contains specular reflected light)/ SCE(not contain specular reflected light)measure at same time.


    Compliance standards:CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,DIN5033 Teil7,


    JIS Z8722 Condition C,ASTM E1164,ASTM-D1003-07

    Transmission:d/0(diffuse illumination, vertical reception)


    Sensor


    Differential spectrum engine


    Spectroscopic method


    Concave grating


    Integrating sphere diameter


    152mm


    Wavelength range


    360nm-780nm


    Wavelengthinterval


    10nm


    Reflectance measurement range


    0-200%,resolution 0.01%


    Lighting source

    Pulsed xenon lamps andLED


    Ultraviolet measurement

    IncludesUV,400nmcutoff,420nmcutoff,460nmcutoff


    Measuring time

    Single mode<2s

    Lighting/measurin g calibers


    Reflection:XLAV Φ25.4mm/Φ30mm;LAVΦ15mm/Φ18mm;MAVΦ8mm/Φ11mm;SAVΦ3mm/Φ6mm


    Users can customize the calibre, and the calibre switch is automatically recognized


    Transmission:Φ17mm/Φ25mm


    Transmission measurement specification

    Sample height and thickness:height is not limited, thickness≤50mm

    Repeatability **


    ΔE*ab≤0.01,

    Spectral reflection/transmittance ≤0.1%


    ΔE*ab≤0.005,

    Spectral reflection/transmittance ≤0.1%

    Inter-Instrument Agreement**


    XLAV ΔE*ab 0.15


    XLAV ΔE*ab 0.12


    XLAV ΔE*ab 0.08

    Long-term repeatability***


    XLAV chroma value:standard deviation ΔE*ab within 0.01(under constant temperature conditions,the white correction plate is measured every hour within 24 hours)


    Standard observer


    2°Standard observer and 10°Standard observer


    Viewing light source


    A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84,ID50,ID65,


    LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-8


    Language

    Simplified Chinese,English, Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean,German, French, Polish


    Display content

    Spectral data,Spectrogram, chromaticity data, chromaticity Data, chromaticity map, Pass/Fail judgment, Simulation color, Color evaluation, fog, liquid chromaticity, Color bias


    Color space


    CIE LAB,CIE LUV,LCh,Hunter Lab,Yxy,XYZ,Musell,s-RGB,βxy


    Chroma index


    WI(ASTM E313-20,ASTM E313-73,CIE,AATCC,Hunter,Taube,Berger Stensby),YI(ASTM D1925,ASTM E313-20,ASTM E313-73),


    Tint(ASTM E313-20),Isochromatic index Milm,color fastness,color changing fastness,ISO brightness,R457,A density,T density,E density,M density,APHA/Hazen/


    Pt-Co((platinum-cobalt index),Gardner(Gardner Index),Saybolt(SeibertIndex),Astm color,fog, total transmittance, covering power, force, intensity


    Color difference formula


    ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc,ΔE*94,ΔE*00,ΔEab(Hunter),555color tone classification


    Storage


    8GB


    Screen size


    7-inch capacitive touch screen


    Operating system


    Android


    Power source


    Dc regulated power supply


    Operating temperature and humidity


    5~40°C,relative humidity 80%(35°C)below no condensation


    Storage temperature and humidity


    -20~45°C,relative humidity 80%(35°C)below no condensation


    Accessories

    Power adapter,USB cable, transmission fixture, software U disk, black cavity, white board, green board,30mm aperture,


    18mm aperture,11mm aperture,6mm aperture,support table,cuvette,damping handle


    Optional accessories

    Heating transmission jig(including control circuit),vertical bracket,pneumatic jacking rod(includingcontrol circuit),small sample holding accessories,reflection cupping plate,fiber test box,

    micro transmission jig, rod box, European standard plug, American standard plug


    Port


    RS-232,USB,USB-B,Bluetooth


    Camera positioning

    Ultra HD camera(1400dpi)


    Automatic calibration


    √(Can greatly improve the long-term repeatability of the instrument)


    Fluorescence calibration

    √(Can automatically adjustthe UV intensity,and ensure that the value of the instrument is highly consistent with that of other imported instruments when measuring materials containing fluorescence)


    Brightness calibration


    √(Through the brightness calibration algorithm, the real color of ultra-dark samples is restored)


    Others

    The instrument can be measured sideways,up and down (using accessories); Automatic temperatureand humidity compensation function; PC side software save sample image function

    ※After instrument calibration,the white correction plate was measured 30 times at 5-second intervals to measure the standard deviation of the result in XLAV caliber

    ※※Based on 23°C,the average value of XLAV aperture measurement of 12 swatches of BCRA Series is measured

    ※※※XLAV chromatic value:standard deviation ΔE*ab within 0.1(0℃-40℃ Arbitrary temperature variation)


    Quality DS-37D Touch Screen Benchtop Spectrophotometer Differential Spectrum Engine for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CHNSpec Technology (Zhejiang)Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)